Microwave radiometer, Circuit parameters, Miniature radiometer, Core body temperature measurement, Temperature sensors, Wearable sensors, Non-invasive passive measurementAbstract
This paper presents a new circuit of the miniature microwave radiometer for wearable devices, which can be used to monitor the core body temperature (CBT) of internal human tissues continuously 24/7. The measurement results of the proposed device, as opposed to the known miniature wearable radiometers, remain unchanged when the impedance of the examined area varies. We have derived an analytical expression for radiometer measurement error based on parameters of device components. This formula allows accuracies to be estimated and optimal parameters of the circuit to be selected to minimise measurement error at a design stage. It is shown that measurement error is independent of the antenna reflection coefficient and the temperature of the radiometer front-end. A prototype of the single-channel miniature radiometer has 32 х 25 х 14 mm3 dimensions and USB interface communication with PC. A 28-hour run of the device has shown that it is highly stable, and a maximum drift in temperature is 0.15 ̊C. Operating frequency range was 3400-4100 MHz, supply voltage - 5V; power supply of the radiometer in measurement mode is 210 mA; time constant of the radiometer without being averaged is 0.6 sec, at the same time, standard deviation δ = 0.17 ̊С, with further averaging during 4 sec δ=0.052 ̊С, with averaging during 30 sec δ =0.017 ̊C; when there were input reflections R2=0.25, an error in measuring brightness temperature shifted by 0.2 ̊ C; with 10 ̊C variations in ambient temperature the shift was 0.15 ̊C. Introduction of self-contained power supply and wireless communication with smartphone have made it possible to use the proposed radiometer as a wearable device to monitor the temperature of internal tissues and CBT during human activities.
Downloads
490
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Universidad Nacional de Ingeniería
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The authors who publish in Nexo Scientific Journal agree to the following terms:
- Authors retain the copyright and grant the journal the right of the first publication under the license Creative Commons Attribution License, which allows others to share the work with a recognition of the authorship of the work and the initial publication in Nexo Scientific Journal.
- Authors may separately establish additional agreements for the non-exclusive distribution of the version of the work published in the journal (for example, in an institutional repository or a book), with the recognition of the initial publication in Nexo Scientific Journal.
- Authors are allowed and encouraged to disseminate their works electronically (for example, in institutional repositories or in their own website) before and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published works.